PLC Trainer WSB-60P is designed to learn GLOFA PLC from basic to application.
WSB-60P Introduction
- It allows users to carry out various experiments with built-in push button, lamp, buzzer, etc.
- Users can carry out sensor application experiment. It basically contains approach sensor, photo sensor and DC motor.
- Users can carry out experiments conveniently with built-in DC power supply.
- It offers Demonstration Unit 1 which allows users to study various application program.
Experimental List
- Basic Commands Experiments(Basic Commands, Self-holding, Quiz Circuit)
- Function Block Commands Experiment(Timer, Counter)
- Function Experiment(MCS & MCR)
- 1Φ, 3Φ Induction Motor Forward/Reverses Operation by Demonstration Unit 1.
- 3Φ Induction Motor's Direct-on-line Start by Demonstration Unit 1.
- 3Φ Induction Motor's Y- Operation by Demonstration Unit 1.
- Two Lane Road's Traffic Signal Control by Demonstration Unit 1.
- Three Floors Elevator Operation by Demonstration Unit 1.
- Auto Water Pump Operation 1, 2 by Demonstration Unit 1.
- 1 Axis Position Control by Demonstration Unit 1.
CPU
- Control Method : Cyclic execution of stored program, Time-driven operation, Interrupt task
operation - I/O Control Method : Scan synchronized batch processing method(Refresh method)
- Program Language : LD(Ladder Diagram), IL(Instruction List), SFC(Sequential Function Chart)
- Number of Instructions : LD(20 EA), IL(13 EA), SFC(194 EA)
- Processing Speed : 0.2 / Step
- Program Memory Capacity : 128 Kbyte
- Maximum I/O Points : 512 points(With 16-pt modules), 1024 points(With 32-pt modules),
2048 points(With 64-pt modules)
Power Module
- AC, 50Hz / 60Hz
- DC 5V/4A, 24V/0.7A
Digital Input
- Input Point : 16 Points (2 EA)
- Rated Input Voltage : DC 12/24V
- Common Method : 8 Points/1Com
- Insulation Method : Photo Coupler Insulation
Digital Output
- Output Point : 16 Points (2 EA)
- Rated Load Voltage : DC 12V, AC 220V
- Rated Load Current : MAX 2A
- Common Method : 8 Points/1Com
- Insulation Method : Relay Insulation
Base
- 8 Slot (Maximum Number for Module Attach 8 EA)
Vibration-proof Module
- Vibration-proof for Non-use Slot
Accessory
- Experimental Manual : 1 Copy
- Connecting Cord : 1 Unit
- Communication Cable, Power Connecting Cable : 1EA
- 프로그래밍 Tool 사용방법
- 기본명령어 실험실습 (기본명령어, 자기유지, 퀴즈)
- 평션블록 실험실습 (타이머, 카운터 등등)
- 평션 실험실습( MCS & MCR 등등)
- Demonstration Unit1을 응용한 1Φ, 3Φ 유도 전동기 정/역 운전 실험
- Demonstration Unit1을 응용한 3Φ 유도 전동기 직입기동, Y-Δ운전 실험
- Demonstration Unit1을 응용한 2차로 교통 신호등 운전 실험
- Demonstration Unit1을 3층식 엘리베이터 운전 실험
- Demonstration Unit1을 자동 양수 장치 운전1, 2 실험
- Demonstration Unit1을1축 위치제어 운전 실험